If the variable speed pump is set too low, readjust it accordingly. A pool heater is a necessity during the winter and even across all seasons for people living in colder regions. Become a Partner Fluidra Pro Academy. Failure to follow warning notices. Copyright 2023 PoolPartyApp.com ALL right reserved. Red LED above icon indicates unit is heating, hold the MENU key for 7 - 10 seconds. Immediately switch off main gas supply. Improper installation and/or operation will void the warranty. Do not touch any electrical switch; do not use any phone in your building. Jandy Ultra-Compact And Energy-Efficient Gas Pool Heater User Manual WARNING: The . Professional Maintenance And Service, Page 44: Special Service Issues - Premix Combustion System, Page 45: Burner Throat Pressure Adjustment, Page 54: Exploded View Of Heat Exchanger, Bronze. Improper installation and/or operation may void the warranty. Description Installation and Operation Manual: JXi Heater. How to Fix: You can take a couple of steps to ensure the heater works again. Immediately call your gas supplier from a neighbor's phone. Jandy JXi 400N Not Igniting - Help | Trouble Free Pool Measure the resistance between the 2 wires you removed from the solenoid coil on the inlet side of the gas valve. sebring jx paintable jxi. Are my medical conditions an issue for swimming in the hot tub? Improper installation and/or operation can create carbon monoxide gas and flue gases which can, cause serious injury, property damage, or death. 2 WARNING If these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death. Free Downloadable PDF Owner's Manual. Improper installation and/or operation will void the warranty. JXi ASME models are available with robust heat exchanger tubes and corrosion resistant bronze headers to meet the high stresses of commercial installations. Jandy LRZ Electronic Installation And Operation Manual LXi swimming pool heater pdf manual download. User Manuals, Guides and Specifications for your Jandy PRO Series JXI260 Swimming Pool Heater. Get the air out of the gas line by altering the ignition sequence. You are taking the brown and yellow wires off of the gas valve and doing nothing with them. Find the proper setting on the pool heater temperature control and use the Set Point Lockout NOTE: If I leave the brown and yellow wires attached to the male spade disconnects on the valve AND I place my test leads directly on the exposed portion of the male spade disconnect, I NEVER see the 26.2V during the startup. If you cannot reach your gas supplier, call the fire department. success: function(response) { App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. 2022-03-10 10. A Jandy pool heater ideally requires two openings where its installed for adequate ventilation, usually maintaining a 12-inch gap above the floor for one opening and another 12-inch gap from the ceiling. Bad Pressure Switch 4. Pool Heat . Choose Pool or Spa. Is it something very specific to this heater, or is it just a general tube. Flawless operation, never had an issue ever. The JXi heater sets the standard in pool and spa heating technology with its ultra-compact size, lightweight design, and energy-efficiency options that save on electrical costs. 00. I have a jandy jxi and after 2 minutes I get a fault error, Why You Should Only Work With A Qualified Professional. Before installing this product, read and follow all warning notices and instructions that, accompany this product. The JXi sets a new standard in pool and spa heating technology with its ultra-compact size, lightweight design, and installation flexibility, making it a top choice for pool professionals and pool owners everywhere. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:214-764-8551 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back Pool Heat Pumps 2021-08-19 Jul 21, 2013 36,052 Northern NJ Pool Size 35000 Surface Plaster Chlorine Salt Water Generator SWG Type Pentair Intellichlor IC-60, Page 24 ENGLIS Jandy Pro Series TruClear Chlorine Generating System | Installation Operation Manual Section 7. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Jandy JXi 200 Installation And Operation Manual The LXi includes the necessary, controls to switch valves from pool to spa. Best Sellers View and Download Jandy LXi installation and operation manual online. #1 I have a Jandy JXI400 heater. 11. Follow the gas. Faulty Ignition Various issues may arise with your heater. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. |. FL. Page 4 EGLISH Jandy Pro Series, JXi Gas-Fired Pool & Spa Heater | Installation & Operation Manual 2. $(obj).find('span').text(response); Check the power board to ensure connection to the gas valve. Operating Instructions, Page 38: Swimming Pool Energy Saving Tips, Page 42: Ignition Control Led Service Codes, Page 44: Cabinet Assembly Spare Parts List And Exploded Parts Diagram, Page 45: Heat System Spare Parts List And Exploded Parts Diagrams, Page 47: Water System Spare Parts List And Exploded Parts Diagrams, Page 48: Electrical System Spare Parts List And Exploded Parts Diagrams, Page 52: Install Pressure Relief Valve Kit #R0336102, Page 53: Cabinet Assembly Spare Parts List And Exploded Parts Diagram, Page 55: Water System Spare Parts List And Exploded Parts Diagrams. Skip to main content.ca. Remove the yellow and brown wires from the gas valve. Corporate Aqua Products Blueriiot Grand Effects Jandy Polaris Zodiac Pool iAquaLink Blog Nature2 Cover-Pools. Have you checked the resistance (ohms) of the 2 gas valve solenoid coils? Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. It is also used as a sensor to prove the ignition/flame. Jandy JXi 200 Installation And Operation Manual Jandy LXi CHECK IGN CONTROL fault | Trouble Free Pool Jandy Jandy Pro Series Capacitor Blower, Jxi Kit. Before installing this product, read and follow all warning notices and instructions that accompany this product. All wiring must be done in accordance with applicable local and National codes and requirements. paging. Document ID H0286900. If the igniter lights and the heater doesnt work, it could be due to one of the following causes: When this error code shows up on the monitor, the probable causes are: An ignition problem could be a cause for concern and usually has numerous causes: This error code shows up when the heater system is in Maintain Temp mode. Enhance your purchase. Immediately call your gas supplier from a neighbor's phone. PDF JXi Troubleshooting Guide - Pool Supplies Superstore 1 Introduction 2 Manuals 2.1 Altitude Adjustments 3 Repairs 3.1 JXI Igniters 3.2 Flame Rectification Failure 3.3 JXI High Limit Sensors 3.4 Replacing Leaking Heat Exchanger in Jandy JXI Heater 3.5 Fault - Shorted H2O Sensor 3.6 Fault - High Limit, HL 4 Jandy/Zodiac PC Board Repair Introduction Pump is not running. Why You Should Only Work With A Qualified Professional. For indoor installations, as an additional, measure of safety, Jandy Pool Products, Inc. strongly recommends installation of, suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adja-. Step 13 - 25.0V. Kee p reading to l earn about this heater in detai l and what features does it p ossess and is investing in it worth the money. This high-efficiency, low-NOx JXi is 200,000 BTUs in size and accepts propane (Minimum 460 lb propane tank required for , This manual contains information for the proper instal-lation and operation of the Jandy CL and CV Series Cartridge Filters. They keep your water warm and fresh all year long. Green enabled LED above icon will light. Jakarta Condo Bar Patio Collection - Boldt Pools & Spas www.boldtpools.ca. Fluctuating Filter Pump Pressure 2. Do not touch any electrical switch; do not use any phone in your building. Jandy Pool Heater Won't Ignite [9 Easy Fixes] - HeaterFixLab Before opening the filter, blow away any debris from the outside area. Are flue gases harmful to my surroundings? Follow the gas supplier's instructions. 2 WARNING If these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal . Sidewall Ventilation - Provides versatility and ease of installation. JANDY LX or LT LOW NOx TROUBLESHOOTING Fireman's Switch Water Pressure Switch Hi Limit 150 F Hi Limit 135 F Fusible Link Exhaust Limit Temp Switch Air Pressure Switch Transformer Hot Surface Igniter Flame Proving Rod Fuse Low Pressure Hi Lim Sw Ext Sw 1 Air Flo Sw AGS 10 K Ohms Thermistor Temp Sensor MV MV Control will alternately flash REMOTE T-STAT, Remote system must be wired as shown before. May 19, 2018. Jandy Pro Series JXi Low NOx 400000 BTU Natural Gas Heater in Tools & Home Improvement. Heater Troubleshooting Guides Table Of Contents 1 F STEP 2 Check Transformer 24 VAC between Red (2) wire and Yellow (1) wire on Transformer? Connection to Jandy Control - RS 485 JXi CONNECTED TO AQUALINK RS AT RS 485 LINE There are two ways of connecting a Jandy JXi heater to the AquaLink RS. Jandy Heater LXi Low NOx poolsupplyworld.com. You will get much more visibility by. United States Residential Pool Heaters and Heat Pumps JXi Pool & Spa Heater JXi Pool & Spa Heater 4.8 Stars (227 Reviews) Find a Dealer Overview Downloads Features Reviews Accessories Models Frequently asked questions JXi Pool & Spa Heater An Ultra-Compact and Energy-Efficient Gas Pool Heater Little over 4 years old. Temperature may be raised or lowered. If they are significantly more or less, you have a problem with the gas valve. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[728,90],'poolpartyapp_com-banner-1','ezslot_14',140,'0','0'])};__ez_fad_position('div-gpt-ad-poolpartyapp_com-banner-1-0'); Malfunctioning combustion could result from the wrong gas being installed, a lean or rich air and fuel mixture that can cause a low supply of pressure, a high supply pressure, or too much or too little combustion air in the system. Jandy JXi Pool & Spa Heater: Energy Efficient Pool Heater | Jandy Page 5: Section 1. Please refer to Section 4.3 of this manual for, FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified, in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements, exists. Lets take a detailed look at some of the most common issues to troubleshoot with a Jandy heat pump. All wiring must be done in accordance with applicable local and National codes and requirements. Review Subject Required. Support Register Why a Jandy Pro Residential Catalog Commercial Catalog. Hello , This is an inactive thread. $66.30 $33.00 (You save $33.30 ) SALE ALERT! Gas-Fired Pool and Spa Heater, Natural Gas and LP. Jandy , A Jandy LXi heater optional control can be installed remotely with 22AWG 4 conductor wire up to 300. Whether your Jandy turns on and off abruptly, ignites slowly, or has aflame with a short yellow streak that then goes out, the pool will not feel the same and will. INSTALLATION AND OPERATION MANUAL Jandy Pro Series JXi Gas-Fired Pool and Spa Heater Models 200, 260, 400 IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY WARNING DAMAGE, PERSONAL INJURY, OR DEATH. The MENU, 6) Load Defaults - Resets factory settings, Follow directions from Service Set-up Mode, (see above), Maintain Temperature (Service, mode with the Maintain Heat feature, press. 2018-05-20 Jul 6, 2011. Gas-Fired Pool and Spa Heater, Natural Gas and LP. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Thoughts? Document ID H0493300 Description VersaFlo Integrated Bypass Installation Manual for JXi Pool and Spa Heater File Size 3.2 MB | File Type PDF Document ID 5878_SL Description JXI Brochure File Size 1.35 MB | File Type PDF Document ID 5872_SL Description JXI with VersaFlo Brochure File Size 637.56 KB | File Type PDF Description JXi 400NK 2D What are the chances I received a bad gas valve out of the box? 2017-10-25 Jandy Pro Series JXi Pool Heater Troubleshooting Guide. additional control (p/n R3008800) can also be wired for. Re-stocking soon. Professional Service And Maintenance, Page 40: Cabinet Assembly Spare Parts List And Exploded Parts Diagram, Page 41: Heat System Spare Parts List And Exploded Parts Diagrams, Page 43: Water System Spare Parts List And Exploded Parts Diagrams, Page 44: Electrical System Spare Parts List And Exploded Parts Diagrams. JANDY LXI QUICK MANUAL Pdf Download | ManualsLib Jandy pro series gas-fired pool and spa heater, FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in, which the product will be installed where such state or local requirements exists. PDF Jandy LXi Heater Quick Start Guide - RoyalSwimmingPools Jandy LXI Heaters - Further Reading | Trouble Free Pool This would seem to suggest a bad gas valve but I already replaced the gas valve with a brand new one. Hide . Does the gas pressure change at all when the heater tries to ignite? To keep these units running at top efficiency, the digital controls will display a code when something needs service. Before installing this product, read and follow all warning notices and instructions that accompany this product. Learning how to troubleshoot these common issues will make your pool time more enjoyable. 2023 Zodiac Pool Systems LLC - All rights reserved. If these instructions are not followed exactly, a re or explosion may result. Should read between 50-500ohms. Now, the tubing that goes between the burner throat and the burner is burnt/corroded. Doheny's DIY Pool Care Help Center. Look for loose connections with the igniter, gas valve, and ignition. Easy Replacement - 3-port header for easy plumbing and drop-in replacement of MasterTemp, Max-E-Therm, and Jandy Pro Series heaters. Table Of Contents Jandy Pool Heater Won't Ignite [9 Easy Fixes] 1. How to Troubleshoot Jandy Jxi/Lxi Pool Heaters YES NO (See Photo), It does not seem like the gas valve is opening and releasing gas, Gas pressure incoming is measured at 7.6 in WC, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Air pressure switch tubing is damaged, disconnected, or interfered with, Airflow is restricted somewhere in the pathway. The Jandy Pro Series JXi pool/spa heater is a blower assisted, internal combustion chamber, residential heater. Description Jandy Pro Series LXI Gas-Fired Pool and Spa Heater Manual. Step 10 - 26.4V (had to turn on heater starting w/ this step) Step 11 - 26.1V. What tools and equipment do I need to have before troubleshooting a Jandy pool heater? Jandy pool heaters are a marvel, as they last a long time and do an excellent job of consistently keeping your pool warm and cozy. Raise heating setpoint, using UP, Control will indicate heater in Spa Heat mode and. 237. I opened my pool two weeks ago. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in, which the product will be installed where such state or local requirements exists. The gas valve does not look new. A Jandy LXi heater optional control can be installed remotely with 22AWG 4 conductor wire up to 300'. The. Manuals; Brands; Jandy Manuals; Swimming Pool Heater ; LXi; Jandy LXi Manuals Manuals and User Guides for Jandy LXi. If you cannot reach your gas supplier, call the fire department. ZODIAC POOL SYSTEMS INC Jandy Valve Actuator - 4424. Follow the gas supplier's instructions. Check whether the variable speed pump is set too low. Read these installation and before setting temperature. File Size 7.32 MB. }); JXi Gas-Fired Pool and Spa Heaters Quick Reference Guide Models JXI200, JXI260, JXI330, JXI400. Page 43: Section 10. In the event no such state or local requirement exists, the installer or, maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual, can be followed exactly. For address information see back cover. GOT A FAULT CODE, SHORTED H20 SENSOR AND REPLACED IT. The gas meter is too small or the line from the meter to the heater is too small. 6 LXi Heater | Jandy Pro Series www.jandy.com. PDF Jandy Pro Series JXi ASME Pool and Spa Heater Downloads. str = $(this).attr('id'); Jandy JXi: ASME Heater | Jandy Check to see if the heater has proper ventilation and no blockages.. Electrical Connections, Page 29: Section 7. *Smaller footprint compared to major competitor models. If you are a diabetic or have a medical history of cardiac diseases and blood pressure problems, you should consult with a medical professional before using your pool or. Use size 1/4 in x 2-1/4 in galvanized Anchor brackets do not come standard with the or plated concrete screws and washers. Make sure the filter pump is off and will remain off for the duration of the installation procedure. If you own a digital manometer, use it to check that the offset pressure is -0.2 in W.C. and adjust as necessary. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'poolpartyapp_com-large-leaderboard-2','ezslot_12',111,'0','0'])};__ez_fad_position('div-gpt-ad-poolpartyapp_com-large-leaderboard-2-0'); Generally when the water flow through the heater is minimal or inadequate or when the thermal regulator valve stops working, youll hear knocks and loud noises coming from the heater. You must log in or register to reply here. Database contains 1 Jandy PRO Series JXI330 Manuals (available for free online viewing or downloading in PDF): Quick reference manual . Naturally, they are heavily used during the winter. Regular maintenance and knowing the ins and outs yourself will ensure the heaters give you their best performance, time and again. Troubleshooting WARNING Always turn pump off prior to attempting service or repair. Measure the resistance at the 2 gas valve terminals that you removed the 2 solenoid coil wires from to obtain the resistance of the second gas valve solenoid coil. Jandy Pro Series JXi Heater 400,000 BTU NG - Elec Ign - JXI400N jandy jxi heater pool pro natural series bypass versaflo gas btu dimensions brochure. The reason two vents are necessary is that the vented air comes internally; therefore, the heater must be located in a place where it is connected to the internal ventilation space inside. Hello Select your address Tools & Home Improvement. if the thermal regulator valve (TRV) is permanently open or opening too soon. Installation and service must be performed by a qualified installer, service agency or the gas supplier. What does FAULT HIGH WATER TEMP mean? #1 Hi, I've been having issues with my heater this year at opening. Professional Maintenance And Service Parameter Jandy Pro Series JXi 400K , The JXi heater sets a new standard in pool and spa heating technology with its ultra-compact size, lightweight design, and installation flexibility, making it a top choice for pool professionals and pool owners everywhere. La velocidad mnima de cebado es de 1500 RPM para las bombas equipadas con Jandy Pro Series SVRS. Do not touch any electrical switch; do not use any phone in your building. jandy heater lxi pool asme nickel cupro heaters heat gas equipment pro series. Pumps, Filters, and Plumbing. and instructions may result in property damage, personal injury, or death. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. We have 1 Jandy PRO Series JXI400 manual available for free PDF download: Quick Reference Manual . In the event no such state or local requirement exists, the installer or, maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual, can be followed exactly. This means the filter pump is switched off and therefore doesnt require any service. Check the vent pipes for any bird, insect, or rodent presence that could cause obstructions. Why is my Jandy LXi/JXi heater not turning on with automation? I've already replaced a couple faulty parts. enabling the remotes options on the controller. In the event no such state or local requirement exists, the installer or maintainer must be a professional with, sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual, can be followed exactly. Jandy Pro Series Jxi Troubleshooting Guide Recipes Dec 6, 2020; Add bookmark #1 I have a Jandy JXI400 heater. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Jandy R0456900 Laars LXi Heater Ignition Control | EBay www.ebay.com. jandy lrz jxi. FOR YOUR SAFETY This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exist. monoxide gas and flue gases which can cause serious injury, property damage, or death. The UP/DOWN arrows will toggle to options: For Aqualink RS connection use 'REMOTE T-, Select SPA. Cart All. Jandy Pro Series JXi Pool Heater Troubleshooting Guide btu lxi jandy pool heaters vent kit side zodiac heater nox low parts. Use the digital manometer to obtain a differential from the blower throat and the gas valve port. As industry leaders committed to giving you the perfect pool experience, we: find a pool pro. 3. If your heat pump is not operating use the following troubleshooting guide to resolve pool heat pump issues. Youll find the drain at the bottom of the filter; allow excess water to flush out. Ultra-Compact Lightweight Design - Easy to store, transport, and install, the JXi pool and spa heater is 38% lighter with a 28% smaller footprint. Open , Jandy Pool Heater Wiring Diagram - Wiring Diagram wiringdiagram.2bitboer.com. Jandy JXi 200n Blower not turning on - Running out of troubleshooting steps, Hear a clicking sound, ignitor stops glowing, Approx 30 seconds later Ignitor begins glowing again, same as above, Water Pressure Switch - Brass nuts were cracked anyway, I noted that the two wires connected to the Exhaust Temp Fusible Link, were blackened and charred. I've looked everywhere, and can't find any info on this specific tube. 100% satisfaction guarantee Get all the answers you need. This feature on the heater requires. 5. Next Day Delivery. Walked over to heater and it said "CHECK IGN STEPS". Comments Required. JXi Pool & Spa Heater | Jandy I decided to get out and turned it off. The, different functions. Jandy Pro Series JXi Pool Heater Troubleshooting Guide. Description Jandy JXi Heater Installation and Operation Manual. File Size 3.2 MB. Does the Fenwal ignition module show any fault codes? First, turn off the heater. Check with the circuit breakers and the power board to ensure its not a simple power outage. To successfully troubleshoot all kinds of pool heater issues, you will need a flathead screwdriver, safety eyewear, a Phillips screwdriver, a pipe wrench, an adjustable wrench, a pair of gloves, a 3/16 Hex key, channel locks, a digital differential manometer, a tape measure, a voltage meter, a PVC pipe cutter, and a power drill. if the heater size is inappropriate for the pool. Parts4heating.com: Pool Heater Parts Jandy LX / LT 400. Each has its own set, temperature. Database contains 1 Jandy PRO Series JXI260 Manuals (available for free online viewing or downloading in . Pool and spa heater natural gas or lpg (40 pages), Manual will be automatically added to "My Manuals", Vent Pipe Sizing And General Installation, Inspection and Replacement of Existing Vent System with New Components, Pressure Relief Valve and Temperature Relief Valve, Auxiliary Components, Chlorinators, Ozone Generators, and Sanitizing Chemicals, Converting the Heater for a 120V Power Source, Optional Pump Connection (Maintain Temp Feature), Connection to a Remote Pool-Off-Spa Selector (3-Wire Connection), Special Service Issues - Premix Combustion System, Swimming Pool Heater Zodiac Jandy Legacy LRZ Millivolt Installation And Operation Manual, Swimming Pool Heater Zodiac JXI200N Workbook, Swimming Pool Heater Zodiac JXi 200 Installation And Operation Manual, Swimming Pool Heater Zodiac RED LINE Instructions For Installation And Use Manual, Swimming Pool Heater Zodiac Legacy LRZ Installation And Operation Manual, Swimming Pool Heater Zodiac RE/U Instructions For Installation And Use Manual, Swimming Pool Heater Zodiac DT850E Instructions For Installation And Use Manual, Swimming Pool Heater Zodiac RE/L Instructions For Installation And Use Manual, Page 9: Section 2. ZODIAC POOL SYSTEMS INC Jandy 2" Straight Check Valve - 7305. 1.2 Consumer Information and Safety The LXi heater is designed and manufactured to provide many years of safe and reliable service when installed, operated, and maintained according to the information in this manual and the installation , Jandy Part Code: JXIHRK. Low Gas Supply Pressure 8. Zodiac Jandy LXi Installation And Operation Manual . Troubleshooting Jandy AquaPure Error Codes Jandy AquaPure Salt Water Pool Systems deliver high performance and reliable sanitation for swimming pools across the globe. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the . The LXi is designed for Category III NOTE For approved side wall vent kits and specific venting with a maximum of 25 ft (7.6 m) of vent pipe installation instructions, see Section 11, and up to three (3) elbows. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Gave it maybe 5-10 minutes. File Type PDF. Gas-fired pool and spa heater, natural gas and lp . Database contains 8 Jandy Pro Series Manuals (available for free online viewing or downloading in PDF): Quick start manual, Installation and operation manual, Manual , Owner's manual, Installation manual . Jandy Pool Heat Pump Troubleshooting Guide Kit Components: S/S Jandy Appliance Adaptor; S/S Vertical Drain Tee; Condense Kit; S/S Pipe 2 4 x 24 S/S 4 x 90 Elbow; S/S Pipe 4 x 12 S/S Wall Thimble; S/S 4 Termination Coupling; Z Vent Sealant; Installation Manual, 2021-06-22 On that note, in this article, we will talk about Jandy Pro Series JXi 400K BTU Low-NOx Natural Gas Swimming Pool and Spa Heater JXI400N one among the l atest mode l s you wi ll find in the market.