Maybe also use the raw reading of the USB port command listed in the wiki, see if that also messes with the pump. What to Do for Your Pool After a Power Loss. 19799 root 20 0 12284 2064 1920 R 64.1 0.1 10:14.04 aqualinkd Here's the log with debug level and serial_readahead set in the config. place to buy one, also are there instruction for installing it? If you use that, I'd be interested to see if anything changes on this problem. http://aqualinkd.ip:port/debug.html will get you to the debug page. Ultimately RS-6 Combo and RS-2/6 Dual use the exact same key codes, so everything should work, just have a 1 more aux button that won't do anything for you. CPU Voltage: 0.8625 --Stefan Jul 2 17:15:29 aqualinkd aqualinkd: Config force SWG = YES
The Only Pool Pump Troubleshooting Guide You'll Need - Mr Pool Man It got me thinking that if I am ever away from the house and we lose power, I would need to be aware and log back in and turn on the pump. If you could download and run it, it'll check a few thinks on the Pi to see if there have been any system problems reported since last boot (like heat / power / voltage) that may cause a slowdown.
Pentair VS Superflo Pump Not Turning On At Correct Time Or At All Then, waiting a few minutes and re-enabling AqualinkD. It may not display this or other websites correctly. One, the pump relay has to be turned on. Sent: Tuesday, June 2, 2020 8:59 PM The contactor only gives the pump power the control wire tell it to turn on. Pool and spa lights heater, spa blower all trigger ok. Do you have a variable speed pump? Heres a step-by-step guide, so your pool and all the people inside remain protected in a power outage. Jun-02-20 17:44:48 PM Debug: PDA Menu Line 4 = POOL MODE ON When can you reset equipment like your filter and heater? 18952 root 20 0 12284 2008 1864 S 2.6 0.1 1:52.83 aqualinkd Jun 18 14:16:08 aqualinkd aqualinkd: Serial read bad Jandy checksum, ignoring going back over your config, you should comment out these two lines extended_device_id=0x40 and extended_device_id_programming = yes, since PDA panel doesn't support either. Notice: RS Serial: Notice: RS Serial: Pentair ID's found Great forum, and I am happy to be a member. Jun 18 09:21:01 aqualinkd aqualinkd: Config read_all_devices = YES When you have a power failure and continue to use water, the pressure switch, which has a gray plastic cover and is located near your well's pressure tank, will have to be reset. Sometimes, maybe once a day or once every other day, this would cause the SWG to go offline and start flashing an error on it's console. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Spa_Heater = label Spa Heater | (The expansion board has no terminators. Messing with it further, I can control the auxiliaries just fine. On my Z4 you hold the up and down arrows at the same time for a couple of seconds. Going to that page shows debugging enabled, but I can't stop it or post anything. Use a pole and a skimmer to remove anything that a suction cleaner cant handle. Ive seen something very similar to this before, but Ill need some time to dig it up. I enabled the serial_readahead config entry. Make detailed notes and take pictures of cracked pipes . I have not tested this recently but will when it happens again. x34|0x10|0x03| (please check OS for performance issues). Very sorry for asking such a long an rambling question, but I hope you may have some insight. Any idea if the system alerts you if the battery goes bad or is that just a manual reminder type of thing? Green background means the heater is ENABLED but not actually heating. Also assume that the RS-485 wires are not connected to the converter. It's a clean install of Raspberry PI OS Lite from a week or so ago and all it runs is AqualinkD. pi@aqualinkd:~ $ sudo vcgencmd measure_volts core If the circulator pump has power but the pump is not spinning then there is an internal problem in the circulator pump or pump motor or its impelller. With those AqualinkD will not even try to read (let alone write) any information to anything other than the control panel using PDA protocol. Your link has been automatically embedded. Looks like I am good there. Hope that works - there are a couple of other things it might be, but this is fairly common. Otherwise contact Jandy tech support or your dealer - who will fwd you to Jandy tech support. The all connects just fine and things seem ok from there. Hello , There was no answer in this thread for more than.
It shows the BAD PACKET error I receive on the quarter hour if the pump is running (09:15:38). Jul 2 17:16:18 aqualinkd aqualinkd: AUX ID Aux_1 label set to 'Air Blower' Testing download speed.. I then set the config to "panel_type = RS-2/6 Dual" . With the dead front panel removed, feed the red 4-pin connector through the bottom access hole into the low-voltage raceway. Notice: RS Serial: ID 0x09 is not used <-- can use for Aqualinkd One, the pump relay has to be turned on. This will catch that and log it. Suggestions for troubleshooting and repair appreciated. Jun-02-20 17:44:48 PM Info: PDA Menu '2' Selectedline 'POOL MODE ON', Last line received 'AIR POOL' Jun-02-20 17:44:48 PM Debug: PDA Menu Line 6 = SPA MODE OFF If you have to clean these contacts, after disconnecting the power use spray contact cleaner and a small brass brush. Notice: RS Serial: Jandy ID's found Does this simulate "selecting" (i.e. Is this the right part - Jandy Aqua Link 3 hp. I'll investigate and report back. Notice: RS Serial: ID 0x60 is not used <-- can use for Aqualinkd (PDA mode only)
iAqualink and auto pump on after power outage? - Trouble Free Pool It's a simple board that's way over priced if you bought it from a pool store!) Notice: RS Serial: ID 0x40 is in use <-- Onetouch device Jun 18 11:16:22 aqualinkd aqualinkd: BAD PACKET Jandy Packet | HEX: 0x10|0x02|0xef|0x10|0x02|0x20|0x02|0x00|0x00|0x00|0x00|0x00|0 Attached is a quick set of log files.
Water Pump Won't Turn On - 10 checks for a water pump - InspectAPedia Great forum, and I am happy to be a member. Jul 2 17:15:29 aqualinkd aqualinkd: AqualinkD is using use ONETOUCH mode for VSP programming Pool Pump not Turning On? 1. We don't have ant problems, but I did notice a. spider nest so maybe that's what happened. When running that, if the problem doesn't happen, then fire up aqualinkd, wait until 1 or 2 mins before the problem usually happens, go to the debug page and enable serial debugging, wait for the problem to occur, turn off serial debugging, download the file and post that. Other times is when there is a Aqualink complete restart, about 50% of the time, the system will come back up and it seems like the iAqualink/AqualinkD is fighting or something. bfrench http://www.poolspaforum.com/forum/index.ph=&pid=72514, The link you sent me was the exact same problem I'm having. Turn . Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Aux_7 = label NONE | top - 11:20:52 up 10 days, 18:04, 2 users, load average: 0.02, 0.01, 0.00 Have a question about this project? On 3/15/2009 at 11:08 PM, Pool Clown said: Unfortunately, your content contains terms that we do not allow. The procedures in this manual must be followed exactly. Next reset time and date, and functions. It should be here in a couple of days. Please consider.
[SOLVED] Pool pump won't turn on - inground pool If it goes off, then thats it. . Also, in MQTT there are a lot of messages back and forth about the aquapure system. Jun 18 09:21:01 aqualinkd aqualinkd: Config idx spa temp = -999 The 2nd RS485 log does have the bad checksum error. (ie it's programming something). Not sure about your panel but my iAquaLink RS485 connection (the 4 control wires) uses the same terminal block as the RS485 data wire to the pump. All the pool equipment is very non specific as to whats terminated and what isnt, so kinda trial end error on specific versions of equipment as to how you can wire it, On Jun 2, 2020, at 9:55 PM, smurry ***@***.
sudo ./release/serial_logger /dev/ttyUSB0 -rsrd -d -p 5000000000
Installed iAquaLink - pump won't turn on | Trouble Free Pool Jun-02-20 17:44:48 PM Debug: PDA Menu Line 3 = 13 root 20 0 0 0 0 S 0.0 0.0 0:00.00 cpuhp/0 Thats where the filter pump relay is usually. Tried to set it to 0 and didn't notice any difference in error timing but CPU usage went up to 60-70%. They must have reduced the core voltage in the Pi4 for some reason. Also send the output of serial_logger run in debug mode started just before the problem occurs, something like. It would seems that the necessary commands aren't going to the pump correctly. Use the following To do that.
How to Reset or Re Start Your Water Well After a Power Failure I just had a power outage and noticed that if I did not manually turn the pump back on via the app after power was restored, it would not go on automatically. How long will the pool pump have no power? The logging does take a lot of cycles, can you try setting logging to notice just see if that helps, (you'll still see the errors). turned off). Electronic controllers (28 pages) Control Panel Jandy AquaLink RS Owner's Manual. It appears that aqualinkD is sending some messages out that cause this behaviour, but I can't track it down in the logs.
Turn off the pool breakers to prevent the equipment from running once power is restored. Jul 2 17:15:29 aqualinkd aqualinkd: Config mqtt_ID = aqualinkd_b827eb18 Display as a link instead, Jun 18 09:21:01 aqualinkd aqualinkd: Config PDA Sleep Mode = NO No noise, no power - it seems like it's an electrical issue. highlighing and pressing "select" on the PDA) the item "POOL MODE ON"? 3 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_gp I have a relatively new (~4 year old) system, which I guess from your description should have hardware termination. Its very finicky, to correctly terminated and Td vs Chain links. Would this message only be in Debug or in Info/Notice log settings ? If youve recently experienced a power outage and have more questions about what to do, contact a pool professional near you. If the pool pump is not coming on at all or turning on and off the issue is surely electrical and there is likely a loose wiring connection or failed capacitor. extended_device_id_programming = no. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Filter_Pump = label Filter Pump | VSP ID 0x60 | PMP ID 1 | I'll go over your latest logs, and once we've seen results from above, probably the next thing to do is to start measuring time for different actions within AqualinkD to see where the problems lie, I'll talk you enabeling that later. This is odd behavior, but I think you may have multiple things going on. Thanks! . Quick suggestion on things that would slow AqualinkD down that you would NOT see from CPU monitoring would be any network latency issues (like network mounted drives) / MQTT server latency, WiFi re-set or re-connect etc. I didn't have the pump identified in the setup. I believe the Rossmont AC pumps are controllable, and they should remember their last settings. No dealers found. Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Aux_4 = label Pool Light | ***>; Author ***@***. We are a registered 501(c)3 non-profit that is funded by user donations. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Aux_1 = label Spa Blower | Sorry it took a while for these debug logs. I have a Pentair VSP, iAqualink, Chlorinator Pro/Goldline, and the RPI0 with AqualinkD. Jun 18 09:21:01 aqualinkd aqualinkd: Config idx water temp = -999 323 avahi 20 0 6036 3164 2724 S 0.3 0.2 27:50.63 avahi-dae+ Use a screwdriver to tighten electrical connections if necessary. However, the actual behavior is that the pump shuts down. March 16, 2009 in All Swimming Pools Types. Ensure all power to the AquaLink power center is off. Step 1 Press the "Menu" button. Great forum, and I am happy to be a member. Stay calm, and direct swimmers to slowly make their way out of the pool. My config file is attached. One more thing, your CPU voltage looks a bit low, it's probably a Pi4 thing that I'm not used to. So it is possible to hear a click but still no pump. I have already replaced the wires once, so I tend to think that the wiring is not the problem, but I will try again to tighten the connections and maybe replace the wires again to see if this resolves the issue. Jul 2 17:15:29 aqualinkd aqualinkd: Config mqtt_user = mqtt_hassio read_all_devices = no No need to get the whole of AqualinkD git, the following will do it for you. references I'll post an update in a few hours, lets see what we can do about the "Too slow in replying" messages. Thanks for posting. Ensure all power to the AquaLink power center is off. This is a problem because it means my pump won't turn on at the designated times. Sign up for a free GitHub account to open an issue and contact its maintainers and the community. 19048 pi 20 0 10188 2908 2548 R 0.7 0.1 0:00.88 top privacy statement. How cold is out outside? I just did that, turned on the filter pump and it all worked as normal. SERIOUS ERROR on RS485, AqualinkD was too slow in replying to message! The problem is, to make the test also slows down the reply, so kind-a catch 22 going on, so I don't want to enable this by default. Jun 18 09:21:01 aqualinkd aqualinkd: Config mqtt_dz_sub_topic = (null) You will get much more visibility by. force_SWG = no Jun 18 09:21:01 aqualinkd aqualinkd: Display warnings in web = NO Jul 2 17:15:29 aqualinkd aqualinkd: Starting MQTT client to 192.168.1.6:1883 If the motor seems to be overheating then that could be an overloaded circuit or there is something jammed in the impeller of the pump. This works fine about 98% of the the time. 0x11 is set % command, 0x41 is 65%. I must say that everyone here is great with all the helping and knowledge! Jul 2 17:15:29 aqualinkd aqualinkd: Config device_id = 0x0a However, in the process of trying out different RS-485 converters, I did discover a significant clue, which confirms that the behavior is not a problem caused by AqualinkD. It does seem to depend on hardware version as so what is and isnt terminated.
Installation and Operation Manual ePump Variable Speed Pump User Interface Your previous content has been restored. But that probably got confusing for pool installers so termination was added in hardware which also forced people to buy the RS485 expansion boards (more money for Jandy). First you should turn off SWG and Extended packet detection in AqualinkD config. You run your pump 24/7 but do you have the Filter/Pump on a program scheduled to run 8 am to 7:59 AM? If you want to check that you would need the manual for your panel to see how to get into setup mode for setting things like the pump type, speeds and assigning aux relays, it's usually in a hidden menu. 4 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_par_gp Just a thought about this, not knowing exactly what this item in the log means. MiB Swap: 100.0 total, 100.0 free, 0.0 used. To: sfeakes/AqualinkD
Jun 18 09:21:01 aqualinkd aqualinkd: Config serial_port = /dev/ttyUSB0 Same problem. JavaScript is disabled. You can post now and register later. If that is the case you can also label the Aux devices while you are at it if they are not already. All other features work as expected. May have slowed the errors some with an average of every 10 seconds, but then a burst of every 1 to 2 seconds. I'm getting the RS Serial: SERIOUS ERROR on RS485 sometimes every second and as long as 10 seconds before the next error. 1759.8 avail Mem, PID USER PR NI VIRT RES SHR S %CPU %MEM TIME+ COMMAND PI health output is: pi@aqualinkd:~ $ sudo ./pi_health.sh Well the breaker at the house, which is a gfci breaker, was tripped. (Easy \u0026 Affordable)https://youtu.be/mJexau0Xt70Swimming Pool Lights Above Ground Pool Lights and Inground Pool Lightshttps://youtu.be/-VCSlQ0dJKcHow to Easily Get Steps Above Ground Pool Deck and Steps (On a Tight Budget)https://youtu.be/7Sj73wlO81sTop 5 Things You Need for Your Above Ground Swimming Poolhttps://youtu.be/d2aJH_jLA8EHow to Easily Put Chlorine in a Pool Like a Pro? First is the output from /var/log/aqualinkd.log. Its set as Error, (really should be notice or warning). Remove the pool cover and check for debris. From: sfeakes ***@***. Upload or insert images from URL. I expect that any of the RS-485 adapters would have this internal, but maybe not. (please check OS for performance issues). Jun 18 16:15:35 aqualinkd aqualinkd: Serial read bad Jandy checksum, ignoring How do I Reset a Jandy AquaLink System? | ehow Sometimes the error will cause the SWG to go off line until AqualinkD is restarted and sometimes it won't. Use a pole and a skimmer to remove anything that a suction cleaner can't handle. The pump relay is working correctly and repeatably with AqualinkD. Now if you turn it loose the pump should stay on and you are back in business. Are they just standard 9vs? NEVER remove the cover of the switch without turning off the breaker and letting anyone that may turn that breaker back on know what you are doing. Jul 2 17:16:23 aqualinkd aqualinkd: AUX ID Aux_4 label set to 'Pool Light' Notice: RS Serial: ID 0x0b is not used <-- can use for Aqualinkd Here's at least the log from today: Jun 18 09:21:01 aqualinkd aqualinkd: Aqualink Daemon v2.0.1 Video of the Day Step 2 Scroll to and highlight "System Setup" using the arrow keys. Thanks for this. It sounds like you have a RS485 termination issue that when you plug the pi in, its drawing more power and therefor taking something else off the buss. Pump still shuts off repeatedly. It could be okay. Aqualink RS enabling Jandy Heater - poolforum.com Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Aux_2 = label NONE | After compiling the new one I get: Notice: RS Serial: Jandy Control Panel Model : RS-2/6 Dual You were right it was the pool filter pump relay. 18957 root 20 0 0 0 0 I 0.3 0.0 0:04.57 kworker/u+ x34|0x10|0x03| This is interesting. Jul 2 17:15:29 aqualinkd aqualinkd: Config use_aux_labels = YES Hope that works - there are a couple of other things it might be, but this is fairly common. Good Luck. Can you post output if these commands when you get a chance, just for my own sanity. Then open drain plugs, pump pot lids and. Jun 18 09:21:01 aqualinkd aqualinkd: Config mqtt_passwd = XXXXXX Subject: Re: [sfeakes/AqualinkD] AqualinkD turning VSP pump on/off repeatedly (. Control Panel Jandy AquaLink RS Troubleshooting Manual. If what AZM says don't work, then it's probably a stuck relay. OK, I did a bit more troubleshooting today. Jun 18 09:21:01 aqualinkd aqualinkd: Starting MQTT client to 192.168.1.6:1883 The power is finally back on. You switched accounts on another tab or window. Jul 2 17:15:29 aqualinkd aqualinkd: Config extra_device_prog = YES The system is a Raspberry PI4B with 2 GB of RAM with the latest Raspberry OS. All button control panel (22 pages) Lighting Equipment Jandy AquaLink RS Installation Manual. Brand new aqualink not turning on the pool. & Sylvan. I'd Jandy PDA Remote time/date keep resetting | Trouble Free Pool Jun-02-20 17:44:48 PM Debug: RS Waiting to send cmd '0x06' (programming). To: sfeakes/AqualinkD ***@***. Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Spa_Heater = label Spa Heater | Pool Pump Not Turning On - (Easy Fix) - YouTube If this does not work you will have to contact jandy and see if the specific remote you have has a replaceable control circuit if not you will have to replace the unit for new. Good Luck Quote Kefbum Members 16 Posted March 16, 2009 For a better experience, please enable JavaScript in your browser before proceeding. Jun 18 09:21:01 aqualinkd aqualinkd: Config deamonize = YES Glad it "seems" to be acting correctly, please keep me informed. Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Solar_Heater = label Solar Heater | With those AqualinkD will not even try to read (let alone write) any information to anything other than the control panel using PDA protocol. You should probably check your wiring. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Aux_5 = label NONE | Jun 18 09:21:01 aqualinkd aqualinkd: Config log_level = 7 Notice: RS Serial: ID 0x08 is not used <-- can use for Aqualinkd Cc: smurry ***@***. Jul 2 17:15:29 aqualinkd aqualinkd: Config mqtt_server = 192.168.1.6:1883 About 100 bucks in nor-cal. I have no idea how good the battery is, is there a way to check the life of it? Today I tailed to log file and tried to capture what was happening immediately before the pump cycled from "on" to "off". Jun 18 09:21:01 aqualinkd aqualinkd: Config override frz prot = NO I believe that the RS-485 is 120 ohm terminated. Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On, Trying to understand Jep-R, AquaLink and iAquaLink interplay, AquaLink Handheld and iAquaLink Not Connecting. By the way, I have an older RS 2/4 board and some other Aqualink parts. Jul 2 17:15:29 aqualinkd aqualinkd: Config BTN Aux_6 = label NONE | 3 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_gp Jun 18 09:21:01 aqualinkd aqualinkd: Config mqtt_aq_topic = aqualinkd 539 mosquit+ 20 0 8808 4784 4300 S 0.3 0.2 4:49.62 mosquitto Jun 18 09:21:01 aqualinkd aqualinkd: Config extra_device_prog = YES Notice: RS Serial: ID 0x31 is not used <-- can use for Aqualinkd (Prefered Extended Device ID) If you have used water during the time while the power was off and now your water won't come on that may be the problem. Installed iAquaLink - pump won't turn on - [STAGING] Trouble Free Pool I just installed the IQ20-RS to get from my Jandy PDA to leverage the iPhone to control the pool. The two (2) outside wires provide the 24 to 28 VAC to the PCB. Fix Heating Zone Circulator Pump that Won't Start or Won't Run Hallelujah! Unplug the RS-485 connector and the pump turns back on. I've seen the SWG run a whole day without going offline on the quarter hour and watched it go off line 3-4 times during the pump run time. volt=1.1000V. I've added some hidden functionality in the next release that may help, or at least catch the problem if my theory is correct. Frequency Capped : OK But, what I think is happening, is you have an issue on your RS485 wiring where when AqualinkD is running (or anything reading/writing) to the usb2rs485 adapter its blocking the pump rs485 messages. After some random period of time (some number of seconds, usually) it turns back on again, then off again, and so on One clue that may help is that whenever the pump cycles, a message on the web interface flashes "Aquapure off." If so, on my PDA if you select POOL MODE ON it will toggle to POOL MODE OFF. (Easy Set Up)https://youtu.be/3Iq4MDnPueoWhat Are the Best Above Ground Swimming Pool Lights? By clicking Sign up for GitHub, you agree to our terms of service and The first RS485.log attached is with the AqualinkD daemon stopped and the following command run about 2 minutes prior to the quarter hour and going for about 2 minutes after. I have a few ideas on what may be causing this. Simultaneously, contact your local pool dealer to schedule time for a pool professional to come out to your pool, assess the damages and provide estimates as appropriate. Jul 2 17:16:14 aqualinkd aqualinkd: BAD PACKET Jandy Packet | HEX: 0x10|0x02|0xe0|0x10|0x02|0x0a|0x02|0x00|0x10|0x00|0x00|0x40|0x6e|0x10|0x03| If you are on a water well and experience a power failure, the pressure switch may be of the type that has to be reset. 8 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 mm_percpu+ 4 root 0 -20 0 0 0 I 0.0 0.0 0:00.00 rcu_par_gp Jun 18 09:21:01 aqualinkd aqualinkd: Config mqtt_user = mqtt_hassio Hello , This is an inactive thread. Jul 2 17:15:29 aqualinkd aqualinkd: AqualinkD is using use ONETOUCH mode for programming (where supported) I've also just added a script to check a few things on the Pi, I can't check it on a Pi4, but if things haven't changed between 3 and 4 it should work. Not sure if it was a good test as I restarted a number of times for version changes and testing. I have ordered a Jandy-branded RS-485 expansion module that I think might eliminate any potential wiring issues. It could be any of 100 things but is it your freeze protection? Jun 17 16:15:20 aqualinkd aqualinkd: Serial read bad Jandy checksum, ignoring. From our residential and commercial water solutions, to industrial water management and everything in between, Pentair is focused on smart, sustainable water solutions that help our planet and people thrive. Upload: 2.65 Mbit/s, The vcgencmd results (I only use the "official" white Raspberry power supplies on my systems): I get this error in the log everytime I click on a button - "WEB: Old stanza, using old method to action" ? Jul 2 17:15:29 aqualinkd aqualinkd: Read Pentair Packets = YES So yes it does need a constant poll From the control panel to keep running. Their home experienced a power ou. It is being practiced by thousands of pool owners just like you. Check the voltage on the secondary transformer (the two (2) outside yellow wires). Here's what I know, though. Jun 18 09:21:01 aqualinkd aqualinkd: Config BTN Pool_Heater = label NONE | The network shouldn't be an issue, but I can test with wired ethernet if you want? That looks like something it trying to send a message to a second control panel. You wouldn't pick these up with TOP or any process monitoring. And congrats on an awesome project. Post the file /tmp/RS485raw.log and also the command output just the part that lists the JandyID's. Jul 2 17:15:29 aqualinkd aqualinkd: Config PDA Sleep Mode = NO read_pentair_packets = no I have always had to RE-Enable the Aqualink at the heater after a power outage because it would go back to "Disabled" due to the interruption, which was a pain but duable. Thanks for any insight you might have. Jul 2 17:15:29 aqualinkd aqualinkd: Config read_all_devices = YES For a better experience, please enable JavaScript in your browser before proceeding. Quote AquaTechPool Members 79 Posted August 18, 2008 Sometimes power fluctuations just before an outage will cause it to trip if the pump happens to be on during that time. You can probably find one on-line cheaper than one at the pool store down the road. Jun 18 16:16:08 aqualinkd aqualinkd: Serial read bad Jandy checksum, ignoring. Bachelor's of Science I have browsed the forums as a guest and solved a few problems. You are using an out of date browser. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase.
Hotels For Sale In France,
Did Feathers Evolve From Scales,
Villa Rosa For Sale Beverly Hills,
Articles A